Skip to content
Strongrate Fiberglass Grating · Factory-Direct, home

Index

Fiberglass Grating Technical Resources

Updated

Use these fiberglass grating resources in three steps: choose molded or pultruded, check the load table at your clear span and design load, then confirm weight, open area and fire rating. Strongrate data comes from its documents: ASTM E84-19a results for six DNV-listed models (flame spread 5 to 20), and its 2023 catalog values, confirmed in your quote and submittal drawings before design use.

Which fiberglass grating resource answers your question?

Fiberglass grating resources by question
Your questionResourceWhat you will find
How much load will it carry at my span?Fiberglass grating load tablesStrongrate catalog deflection tables by span, molded and pultruded1
What does a panel weigh, and how much of it is open?Sizes, weight and open areaCatalog weight, open area and panel sizes for every listed mesh and pultruded type2
What should the project specification say?Fiberglass grating specificationsGuide specification under CSI 06 74 13, with the catalog’s resins, surfaces and chemical-resistance chart3,4
Is it Class 1 fire rated under ASTM E84?ASTM E84 Class 1 fire ratingFlame spread index 5–20 for six DNV-listed models5
How do I cut it and seal the edges?How to cut fiberglass gratingTools, blades, dust control and edge sealing, step by step
How do I fasten and support it?How to install fiberglass gratingSupport bearing, clip spacing and fastening, step by step
Molded or pultruded?Molded vs pultruded fiberglass gratingIndustry comparison, plus the catalog’s glass content: 30–35% molded, 60–65% pultruded
Fiberglass or steel?Fiberglass vs steel gratingIndustry comparison of weight, cost and service life
Something else?Fiberglass grating FAQShort answers that link to the page covering each topic
Values from Strongrate’s 2023 catalog; confirmed in your quote and submittal drawings before design use.

Notes

  1. 1Catalog tables; confirm the values for your span in the submittal before final design.
  2. 2Values as printed in the factory catalog (2023).
  3. 3Maximum service temperatures as printed in the catalog’s resin table; its chemical-resistance chart prints lower maximums.
  4. 4General information from resin makers’ data, as printed in the catalog; testing in the actual environment is recommended.
  5. 5Applies only to the six models listed on DNV certificate TAF0000191 Rev. 1.

Technical data

Guides and comparisons

  • GuideHow to cut fiberglass gratingHow to cut fiberglass grating: blades and tools, cutting steps, sealing cut edges and protective equipment.
  • GuideHow to install fiberglass gratingHow to install fiberglass grating: bearing on supports, span direction, hold-down clips and expansion gaps.
  • ComparisonMolded vs pultruded gratingHow molded and pultruded fiberglass grating differ in manufacture, strength direction, span and cost.
  • ComparisonFiberglass vs steel gratingFiberglass and steel grating compared on weight, corrosion, cost over time and installation, including when steel is the better choice.
  • Quick answersFiberglass grating FAQShort answers to common buyer and engineer questions, each linking to the page that covers it.

Buying and import resources

Strongrate grating is made in Nantong, China, and ships from China, so cost, timing and eligibility questions have their own pages.

Which standards apply to fiberglass grating?

These are the standards and specification conventions the resource pages cite, summarized from the sources listed below. Check the current text and the edition your project or jurisdiction adopts.

Standards cited in these fiberglass grating resources
StandardWhat it coversRequirement or result on recordWhere we use it
ASTM E84Surface burning: flame spread index (FSI) and smoke-developed index (SDI)US guide specifications require FSI of 25 or less (Class 1 / Class A)1ASTM E84 fire rating
ASTM D635Burning rate of plasticsGuide specs require self-extinguishing grating, or no burning past the 1" (25 mm) markFiberglass grating specifications
ASTM F3059Fire integrity of FRP grating on vessels and offshore installationsSix DNV-listed Strongrate models: structural fire integrity L0 (ASTM F3059-15)2Fiberglass grating certifications
OSHA 29 CFR 1910.22(b)Walking-working surfacesEach surface must support its maximum intended loadFiberglass grating load tables
OSHA 29 CFR 1910.25StairwaysStairs carry at least 5× the normal live load, never less than 1,000 lb (4.4 kN) concentratedFiberglass stair treads
2010 ADA Standards §302.3Openings in floor and ground surfacesOpenings must not pass a 1/2" (13 mm) sphereMini-mesh ADA grating
CSI MasterFormat 06 74 13Specification section for fiberglass gratingSection 06 74 13 (older specifications use 06610)Fiberglass grating specifications
ANSI/ACMA FGMC Grating ManualLoad-table, tolerance and testing conventions2nd edition, 2019Fiberglass grating load tables
CSA S806:26 (Canada)Building structures with fiber-reinforced polymers3rd edition, 2026; cite for Canadian projectsFiberglass grating specifications
Summaries, not the standards’ text. Strongrate results on record exist for two of these standards, ASTM E84-19a and ASTM F3059-15, both from DNV Type Approval TAF0000191 Rev. 1 and for six models only.

Notes

  1. 1A specification threshold, not a test result.
  2. 2As stated on the certificate; acceptance for a given location is case by case.

Request a quote

Send your product, quantity, ZIP code and need-by date. Quotes within 1 business day (US Central time) confirm routing and next steps.

Sources
  1. DNV Type Approval Certificate TAF0000191 Rev. 1 (ASTM E84-19a results and ASTM F3059-15 rating) (accessed Oct 15, 2026)
  2. Strongrate product catalog “Your Best FRP Solution” (image PDF, Sep 2023), supplied by the site owner (accessed Oct 17, 2026)
  3. Fibergrate molded grating guide specification (Section 06610) (accessed Oct 15, 2026)
  4. Strongwell Section 06 74 13, FRP Molded Grating and Stair Treads specification (accessed Oct 15, 2026)
  5. OSHA 29 CFR 1910.22, Walking-working surfaces (accessed Oct 15, 2026)
  6. OSHA 29 CFR 1910.25, Stairways (accessed Oct 15, 2026)
  7. U.S. Access Board, Guide to the ADA Standards, Chapter 3: Floor and Ground Surfaces (accessed Oct 15, 2026)
  8. ACMA, 2nd edition national standard fiberglass grating manual (accessed Oct 15, 2026)
  9. CSA Group store, CSA S806:26 (accessed Oct 15, 2026)